Handheld Nutrunner: Handy2000 TouchHAND NUTRUNNER

Control Unit

EH2-HT50 series

Basic Specifications

■ Display screen
High visibillity 7-inch LCD touch screen

■ Communication ports located underside
Less space, less wiring

■ Fastening methods
Torque control, Torque control angle monitoring, Angle control, Torque or angle control, Torque and angle control, Reverse angle control, Yield angle control, Yield control, Inspection toruque method

■ Fastening mode
Selectable among Direct mode (Continuous fastening), Pulse mode (Reaction force reduced) *Not all models

■ Fastening Channel
Max. 99 Channels

■ Fastening Result History
Max. 50,000 records

■ Torque Curve History
Max. 60 records (OK fastening: 30, NG fastening: 30)

■ EtherNet (LAN)
2 Ethernet ports are available. It makes networking simple without the switch (daisy-chainable).
Management software is able to connect through Ethernet, and it is also possible to monitor/control and collect data with a server by the special protocol.

■ FieldBus
Profinet, Profibus-DP, DeviceNet, CC-Link, EtherNet/IP (option)
Bit signal and Word data are assignable, and input and output Bit and Word

■ Remote I/O
By selecting Remote I/O type, it is possible to connect with Omron B7A Link Terminal (16 points, input and output 1 terminal each). This option is recommended when I/O port is not enough or when long distance wiring is required.

■ Batch Counter
nxOK, nxNG output

■ USB Flash Drive
Fastening results can be exported to USB Flash Drive.
Program file can be inported and exported.

■ External Dimensions
W160mm x H316mm x D282mm

■ Weight
8.5kg

Various indications/displays

■ 4 variations of Tightening status menu (Main Monitor)

Information for quality control as Tightening torque on a main display and Angle, Time on a sub display are displayed.

 1. Waveform monitor (Torque, Angle, Current, Speed)

 2. OK/NG Judgment (JOB/COUNT Complete indication)

 3. Selected CHANNEL/JOB indication (Count, Step status)

 4. Tightening result detail (Also sub display item is selectable)

Waveform Monitor (Torque Carve)

Waveform Monitor (Torque Carve)

OK/NG Judgement

OK/NG Judgement

Tightening Result Detail

Tightening Result Detail

■ Status Navigate Function

By touching Information Icon, the detail of Tightening NG/Tool lock/ Alarm/System error is indicated. Without looking into the manual, it is possible to understand the status and find the way for recovery.

e.g. when a tightening NG is reported

e.g. when a tightening NG is reported

■ Editing menu

Mein menu shows Icons which allow to navigate easily.

Large 10 keys are displayed during editing a parameter.

Main menu

Main menu

Editing menu

Editing menu

■ Tightening history menu

It shows the list of tightenings. When a tightening result is touched, it is possible to indicate the detail.
It is possible to check the detail of NG immediately at the station.

Tightening history

Tightening history

Tightening result detail

Tightening result detail

Torque Carve detail

Torque Carve detail

■ Language and background color

Multiple language support

Language: Japanese, English (Chinese, Spanish will be soon available)
Background color: White, Black

Language: English, Background Color: Black

Language: English, Background Color: Black

Language: Japanese, Background Color: White

Language: Japanese, Background Color: White

Variuous functions

■ Cannel

Runs the tool to the preset target torque or target angle and stops, then judges for the tighetning. Various monitor functions are also available as starndard. Tightening program can be created maximum of 99, and it allows 1 controller to work on various chracters of joint. 

■ Multi Channel

Some joints require to run CW-CCW-CW for getting to fit or detecting seizing as a continued movement. It is possible to create such multiple movement as 1 program, and it does not require to switch program after each movement.

■ JOB function

This is a function to allocate multiple tightening as one job. JOB can be created maximum of 99, and maximum of 30 steps can be allocted on 1 JOB.

■ Batch counter function

It counts OK tightening and it outputs nxOK signal when all counts of tightening are judged as OK. It is possible to know if necessary counts of tightening are certainly done to avoid skipped tightening.
Count increment and count decrement are selectable, and also Count OK and Count all are selectable.

Controller Model
Model Option Input Voltage (V)
Fieldbus I/O
DeviceNet Profibus CC-Link EtherNet/IP Profinet Remote I/O P I/O
EH2-HT50-000NNN               Single phase
AC100V-230V
50/60Hz
EH2-HT50-000RNN            
EH2-HT50-000NNP            
EH2-HT50-000RNP          
EH2-HT50-000NDN            
EH2-HT50-000RDN          
EH2-HT50-000NDP          
EH2-HT50-000RDP        
EH2-HT50-000NPN            
EH2-HT50-000RPN          
EH2-HT50-000NPP            
EH2-HT50-000RPP        
EH2-HT50-000NCN          
EH2-HT50-000RCN          
EH2-HT50-000NCP            
EH2-HT50-000RCP        
EH2-HT50-000NWN          
EH2-HT50-000RWN          
EH2-HT50-000NWP          
EH2-HT50-000RWP        
EH2-HT50-000NTN            
EH2-HT50-000RTN          
EH2-HT50-000NTP          
EH2-HT50-000RTP        

How to read the model numbers

How to read the model numbers