Products

Servo Nutrunner: Z50SERVO NUTRUNNER

System Configuration

AXIS Control System/ AXIS Control Multi Spindle System
  • AXIS Control System (AU50 single spindle system)
    System Configration for 1 spindle 1 AXIS Control Unit
  • AXIS Control Multi Spindle System (AU50 multi spindle system)
    Master Link connection enables Maximum of 31 spindles configuration
No. Name Length (m) Model
1 Torque Transducer 5 ENRZ-CVTN2-050
10 ENRZ-CVTN2-100
15 ENRZ-CVTN2-150
20 ENRZ-CVTN2-200
2 Motor Cable 5 ENRZ-CVMN2-050
10 ENRZ-CVMN2-100
15 ENRZ-CVMN2-150
20 ENRZ-CVMN2-200
Motor Cable
(For ENRZ-TU150R-S only)
5 ENRZ-CVMN3-050
10 ENRZ-CVMN3-100
15 ENRZ-CVMN3-150
20 ENRZ-CVMN3-200
3 Resolver Cable 5 ENRZ-CVRN-050
10 ENRZ-CVRN-100
15 ENRZ-CVRN-150
20 ENRZ-CVRN-200
4 Resolver Conversion Cable (*1)
(For ENRZ-TU150R-S only)
1 ENRZ-CVREX-010
5 Torque Transducer Relay Cable 3 ENRZ-CVTN-030
6 ENRZ-CVTN-060
10 ENRZ-CVTN-100
15 ENRZ-CVTN-150
6 Motor Relay Cable (*2) 3 ENRZ-CVMP-030
6 ENRZ-CVMP-060
10 ENRZ-CVMP-100
15 ENRZ-CVMP-150
7 Resolver Relay Cable 3 ENRZ-CVRP-030
6 ENRZ-CVRP-060
10 ENRZ-CVRP-100
15 ENRZ-CVRP-150
8 AU50 Power Cable (*3) 3 ENRZ-CVDC2-030
9 NET Cable
(AU50⇔AU50)
0.2 ENRZ-CVNK2A-002
1 ENRZ-CVNK2A-010
2 ENRZ-CVNK2A-020
10 NET Termination Resistor (*4) ENRZ-CVST3
11 Control Connector (CONTROL) ENRZ-CNAU
12 Management Software ENRZ-PC50
13 Serial Communication Cable 1.5 ENRZ-CVSR-015
5 ENRZ-CVSR-050
10 ENRZ-CVSR-100
14 Serial Printer Cable 3 ENRZ-CVSP-030
5 ENRZ-CVSP-050
10 ENRZ-CVSP-100
15 Check Connector Cable 3 ENRZ-CVCK-030
16 AU50 Battery (*5) ENRZ-BATT

*1 Included with ENRZ-TU150R-S
*2 There can not be used for ENRZ-TU150R-S
*3 Included with AXIS Control Unit (ENRZ-AU50*-**)
*4 One each for MAS Station and last unit of LOC Station required when Multi Spindle System is configured
*5 MAS Station needs 1pcs of battery

Master Control System
  • Simplified logic is available as a standard function, and it enables integration with the fastening system without a PLC
  • Serial connection with PLC enables controlling I/O for maximum of 31 spindles which minimize wiring and setup time
  • Fieldbus is available as an option for expanded networking solution
No. Name Length (m) Model
1 Torque Transducer 5 ENRZ-CVTN2-050
10 ENRZ-CVTN2-100
15 ENRZ-CVTN2-150
20 ENRZ-CVTN2-200
2 Motor Cable 5 ENRZ-CVMN2-050
10 ENRZ-CVMN2-100
15 ENRZ-CVMN2-150
20 ENRZ-CVMN2-200
3 Resolver Cable 5 ENRZ-CVRN-050
10 ENRZ-CVRN-100
15 ENRZ-CVRN-150
20 ENRZ-CVRN-200
4 Torque Transducer Relay Cable 3 ENRZ-CVTN-030
6 ENRZ-CVTN-060
10 ENRZ-CVTN-100
15 ENRZ-CVTN-150
5 Motor Relay Cable 3 ENRZ-CVMP-030
6 ENRZ-CVMP-060
10 ENRZ-CVMP-100
15 ENRZ-CVMP-150
6 Resolver Relay Cable 3 ENRZ-CVRP-030
6 ENRZ-CVRP-060
10 ENRZ-CVRP-100
15 ENRZ-CVRP-150
7 AU50 Power Cable (*1) 3 ENRZ-CVDC2-030
8 MU50 Power Cable (*2) 3 ENRZ-CVDC3-030
9 NET Cable
(AU50⇔AU50)
0.2 ENRZ-CVNK2A-002
1 ENRZ-CVNK2A-010
2 ENRZ-CVNK2A-020
10 NET Cable
(MU50⇔AU50)
0.3 ENRZ-CVNK3M-003
1 ENRZ-CVNK3M-010
3 ENRZ-CVNK3M-030
10 ENRZ-CVNK3M-100
11 NET Termination Resistor (*3) ENRZ-CVST3
12 Management Software ENRZ-PC50
13 Serial Communication Cable 1.5 ENRZ-CVSR-015
5 ENRZ-CVSR-050
10 ENRZ-CVSR-100
14 Serial Printer Cable 3 ENRZ-CVSP-030
5 ENRZ-CVSP-050
10 ENRZ-CVSP-100
15 Check Connector Cable 3 ENRZ-CVCK-030
16 Display Unit Serial Connection Cable 3 ENRZ-CVDP2-030
5 ENRZ-CVDP2-050
10 ENRZ-CVDP2-100
17 Control Connector (CONTROL I/O) ENRZ-CN14-CR
18 PLC Connector ENRZ-CN15-PL
19 EX I/O Connector ENRZ-CN36-EX
20 Remote I/O Connector EH2-FCN04-RM

*1 Included with AXIS Control Unit (ENRZ-AU50*-**)
*2 Included with Master Control Unit (ENRZ-MU50-***)
*3 The last AXIS Control Unit on the system needs 1pcs of Termination Resistor